Development, letting and sale of its own residential stock.37 Thornbury Road, London SW2 4DL.

The five stages → Compliance

Compliance record

One folder per unit holds the certificates and the dated test records. Each has a renewal date, and that date is diarised from the certificate rather than from the last time somebody remembered.

What is held for each unit

The folder is ordered the same way for every unit so that it can be read by somebody who did not build it: certificates by type, then dated test records newest first, then correspondence. Nothing is filed by the date it arrived in the office.

Per unit
RecordWhat it coversRenewed
Gas safety recordevery gas appliance and its flue, by a Gas Safe registered engineerevery twelve months
Electrical installation condition reportthe fixed wiring of the whole unitevery five years, and read again at a change of tenancy
Electrical installation certificatenew circuits and alterations carried out during the worksissued once, at second fix, kept for the life of the installation
Energy performance certificatethe unit as assessedevery ten years, or sooner where the fabric changes
Alarm test recordthat every smoke and carbon monoxide alarm was tested and workingat the start of every tenancy and at each periodic visit
Legionella risk assessmentthe water system, stored water and any dead legreviewed when the system changes or the unit stands empty
Building control completion certificatenotifiable work carried out during the refurbishmentissued once, kept permanently
Window installation certificatereplacement windows, from the installer’s own registered schemeissued once, kept permanently
Deposit scheme certificatethat the deposit is protectedonce per tenancy

Records tied to a tenancy rather than to a date

Three of the records above are checked at the start of every tenancy whatever their renewal interval says, because the tenancy is what they are really tied to.

The alarm test record is taken on the first day of the tenancy, with the tenant present, and the tenant is shown how to repeat the test. The electrical installation condition report is read at a change of tenancy even where its five years have not run, because alterations made during a tenancy — a shelf screwed through a cable, a socket added by somebody else — are precisely what it would catch. The gas safety record is handed to the tenant at the start of the tenancy, and within twenty-eight days of each new record being issued after that.

A renewal that falls due while a unit is empty is still done on its date. An empty unit is the easiest one to get an engineer into, and a certificate that lapses while nobody is living there is the one that is discovered at the worst possible moment, which is the day a tenancy is due to start.

Where the folder goes when a unit leaves

The folder is the pack. When a unit is sold, most of what the buyer’s solicitor asks for is already in it in the order they ask for it, and nothing has to be chased from a contractor after the event. What is sent, and what is held back because it belongs to the tenancy rather than to the unit, is set out on selling a unit on.

How long each record is kept, and who it is shown to, is on the records and privacy page.